M4 Pro Liquid Damage — USB-C PD Controller Corrosion
M4 Pro Liquid Damage — USB-C PD Controller Corrosion
Status: repaired successfully · Channel: LapFix · Published: 2026-07-06 · Runtime: 18:42 Model: MacBook Pro 14" M4 Pro (A3112 / A3185 series) · Board: 820-03487
[stated]Source: YouTube Fault class: USB-C Power Delivery / input power switching
Summary
Liquid ingress produced blue-green copper-carbonate corrosion across the feedback and gate-drive passives around the dual USB-C controllers. All three Thunderbolt 5 ports negotiated only 5 V with essentially no current draw, and the MagSafe 3 LED stayed dark. Cleaning the corrosion and replacing eroded 0201 passives restored a full 20 V / 3 A contract.
Timeline
| Time | Evidence | Observation |
|---|---|---|
| 02:15 | [measured] |
USB-C meter shows 5.18 V on all three ports; current fluctuates 0.00–0.02 A. MagSafe 3 LED unlit. |
| 05:40 | [measured] |
Microscope: thick blue-green corrosion bridging feedback resistors and pass-gate control lines around both USB-C controller ICs. |
| 09:12 | [stated] |
Technician: on M4 Pro boards the USB-C controllers share power gating with the MagSafe controller, so a shorted CC or gate-drive pin freezes the PD handshake across all ports. |
| 12:45 | [measured] |
Corroded 0201 pull-up/series resistors removed, pads micro-scraped, re-tinned with 63/37 leaded solder, passives replaced from a donor board. |
| 15:20 | [measured] |
Re-test: port steps from 5 V to 20.2 V / 3.10 A; MagSafe 3 LED amber. |
| 17:30 | [measured] |
Boots to macOS setup; charging and multi-port Thunderbolt verified. |
Measurements
| Time | Measurement | Value | Context |
|---|---|---|---|
| 02:15 | Voltage / current | 5.18 V / 0.00–0.02 A | All three USB-C ports, before repair |
| 06:30 | Diode mode | 0.015 V | CC1 on the damaged port (abnormal leakage) |
| 15:20 | Voltage / current | 20.2 V / 3.10 A | Fast charging after repair |
| 15:35 | Diode mode | 0.565 V | CC1 after repair |
Diagnostic reasoning
- Observation — every input path negotiates 5 V; MagSafe indicator dark; current stalls at 0–20 mA.
- Stated mechanism — M4-generation power negotiation depends on synchronised bus state machines between the discrete USB-C controllers and the system PMU.
- Inference — ionic conduction across corrosion products bridges the CC
pull-down and gate-enable lines, preventing the controllers from reaching
Attached.SNK. - Resolution — cleaning the corrosion and replacing the eroded 0201 series resistors restored normal impedance (0.565 V diode drop) and enabled the full 20 V / 3 A contract.
Repair procedure
- Disassemble chassis; extract logic board.
- Inspect the USB-C controller perimeter under the microscope.
- Desolder corroded 0201 resistors/capacitors (micro-pencil iron + hot air ~360 °C).
- Clean oxidised pads with a fibreglass brush and flux.
- Fit replacement 5.1 kΩ CC pull-downs and gate-drive series passives.
- Clean flux, verify MagSafe amber indication and battery charging.
Claims audit
| ID | Claim | Evidence | Note |
|---|---|---|---|
| C1 | A shorted CC network on one port locks PD at 5 V across all ports on M4 Pro. | [inferred] |
Directly demonstrated on this unit, but the "shared state machine" wording is the technician's model — verify against the board's actual PD topology. |
| C2 | Modern Macs show an internal RTC date of 1 April because it is Apple's founding date, not an epoch artefact. | [unverified] |
Asserted in passing; not substantiated at firmware level. Do not repeat as fact. |
Related cases
M1 Air 5V Stall — CD3217 1.1V LDO Short[[cd3217-ldo]] — the M1-generation analogue: one PD controller taking down every port.M1 Air 5V Cycling — CD3217B12 Firmware Mismatch[[cd3217-revision]] — PD-bus faults that are not liquid-related.
Provenance: condensed from the video's audio transcript (Google AI Studio); timestamps, refdes and values are as stated in the video and are not independently verified.