M3 Pro Liquid Spill — 5V Stall, Missing SPMU Power-Good
M3 Pro Liquid Spill — 5V Stall, Missing SPMU Power-Good
Status: repaired successfully · Channel: LapFix · Published: 2026-07-14 · Runtime: 14:15 Model: MacBook Pro 14" M3 Pro (A2992) · Board: 820-02918
[stated]Source: YouTube Fault class: Sub-rail regulation / secondary PMU (SPMU) enable
Summary
A Space Black M3 Pro drew a static 5 V / 50 mA with no chime and a black screen.
PPBUS_AON was fully present at 12 V, ruling out a main-rail short, so the stall
pointed at an unfulfilled secondary power-sequence condition. Liquid residue sat
around the Sub-Power-Management Unit (SPMU) buck feedback loop; one 0201 feedback
resistor had rotted to open circuit. Replacing it restored 20 V negotiation and
display.
Timeline
| Time | Evidence | Observation |
|---|---|---|
| 01:50 | [measured] |
5.15 V / 0.05 A static; no chime, black display. |
| 04:30 | [measured] |
PPBUS_AON present at 12.02 V — not shorted. |
| 06:15 | [measured] |
Liquid residue around the SPMU and its buck feedback loops. |
| 08:40 | [stated] |
Technician: M3 Pro boards stay in low-power (5 V / 0.05 A) if the SPMU does not pull the power-good handshake high to the primary PMU. |
| 10:10 | [measured] |
Two badly oxidised 0201 feedback resistors in the SPMU divider network removed; one measures open circuit (OL) off-board. |
| 12:20 | [measured] |
Replacements fitted; board negotiates 20.0 V / 1.15 A and shows the Apple logo. |
Measurements
| Time | Measurement | Value | Context |
|---|---|---|---|
| 01:50 | Voltage / current | 5.15 V / 0.05 A | USB-C meter, initial |
| 04:30 | Voltage | 12.02 V | PPBUS_AON present |
| 07:10 | Resistance | OL | Corroded SPMU feedback resistor (nominal 100 kΩ) |
| 12:20 | Voltage / current | 20.0 V / 1.15 A | Booted into macOS |
Diagnostic reasoning
- Observation —
PPBUS_AONfully present at 12.02 V, yet the board refuses 20 V and draws only 50 mA. - Stated mechanism — the presence of
PPBUS_AONproves the primary charger is running; a 5 V stall therefore indicates an unfulfilled secondary power-sequence condition. - Inference — the open feedback resistor prevents the SPMU buck from stabilising its output, asserting a power-fault flag that stops the main PMU from commanding 20 V.
- Resolution — replacing the open 100 kΩ 0201 resistor restored the rail and the 20 V contract.
Repair procedure
- Confirm
PPBUS_AONpresent and no main-rail short. - Locate the damaged SPMU feedback network under the microscope.
- Desolder the corroded resistors with micro-tweezers.
- Solder-wick and re-tin the pads.
- Fit a replacement 100 kΩ 0201 resistor from a donor board.
- Verify 20 V negotiation and display.
Claims audit
| ID | Claim | Evidence | Note |
|---|---|---|---|
| C1 | On M3, the primary PMU waits on a hardware power-good flag from the SPMU before commanding 20 V from the USB-C controllers. | [stated] |
Consistent with the observed signature; confirm the specific flag name on the board revision before quoting it. |
Related cases
[[dfu-inductor]]Apple Silicon DFU Revive Loop — Inductor Solder Fatigue — another case where a healthy-looking rail collapses under load.[[cd3217-ldo]]M1 Air 5V Stall — CD3217 1.1V LDO Short — a different reason a board sits at 5 V.
Provenance: condensed from the video's audio transcript (Google AI Studio); timestamps, refdes and values are as stated in the video and are not independently verified.