Skip to main content

M3 Pro Liquid Spill — 5V Stall, Missing SPMU Power-Good

M3 Pro Liquid Spill — 5V Stall, Missing SPMU Power-Good

Status: repaired successfully · Channel: LapFix · Published: 2026-07-14 · Runtime: 14:15 Model: MacBook Pro 14" M3 Pro (A2992) · Board: 820-02918 [stated] Source: YouTube Fault class: Sub-rail regulation / secondary PMU (SPMU) enable

Summary

A Space Black M3 Pro drew a static 5 V / 50 mA with no chime and a black screen. PPBUS_AON was fully present at 12 V, ruling out a main-rail short, so the stall pointed at an unfulfilled secondary power-sequence condition. Liquid residue sat around the Sub-Power-Management Unit (SPMU) buck feedback loop; one 0201 feedback resistor had rotted to open circuit. Replacing it restored 20 V negotiation and display.

Timeline

Time Evidence Observation
01:50 [measured] 5.15 V / 0.05 A static; no chime, black display.
04:30 [measured] PPBUS_AON present at 12.02 V — not shorted.
06:15 [measured] Liquid residue around the SPMU and its buck feedback loops.
08:40 [stated] Technician: M3 Pro boards stay in low-power (5 V / 0.05 A) if the SPMU does not pull the power-good handshake high to the primary PMU.
10:10 [measured] Two badly oxidised 0201 feedback resistors in the SPMU divider network removed; one measures open circuit (OL) off-board.
12:20 [measured] Replacements fitted; board negotiates 20.0 V / 1.15 A and shows the Apple logo.

Measurements

Time Measurement Value Context
01:50 Voltage / current 5.15 V / 0.05 A USB-C meter, initial
04:30 Voltage 12.02 V PPBUS_AON present
07:10 Resistance OL Corroded SPMU feedback resistor (nominal 100 kΩ)
12:20 Voltage / current 20.0 V / 1.15 A Booted into macOS

Diagnostic reasoning

  • Observation — PPBUS_AON fully present at 12.02 V, yet the board refuses 20 V and draws only 50 mA.
  • Stated mechanism — the presence of PPBUS_AON proves the primary charger is running; a 5 V stall therefore indicates an unfulfilled secondary power-sequence condition.
  • Inference — the open feedback resistor prevents the SPMU buck from stabilising its output, asserting a power-fault flag that stops the main PMU from commanding 20 V.
  • Resolution — replacing the open 100 kΩ 0201 resistor restored the rail and the 20 V contract.

Repair procedure

  1. Confirm PPBUS_AON present and no main-rail short.
  2. Locate the damaged SPMU feedback network under the microscope.
  3. Desolder the corroded resistors with micro-tweezers.
  4. Solder-wick and re-tin the pads.
  5. Fit a replacement 100 kΩ 0201 resistor from a donor board.
  6. Verify 20 V negotiation and display.

Claims audit

ID Claim Evidence Note
C1 On M3, the primary PMU waits on a hardware power-good flag from the SPMU before commanding 20 V from the USB-C controllers. [stated] Consistent with the observed signature; confirm the specific flag name on the board revision before quoting it.

Provenance: condensed from the video's audio transcript (Google AI Studio); timestamps, refdes and values are as stated in the video and are not independently verified.