M1 Pro Soft Short — PP3V3_S2 Resistive Leakage
M1 Pro Soft Short — PP3V3_S2 Resistive Leakage
Status: repaired successfully · Channel: Paul Daniels · Published: 2024-10-26 · Runtime: 31:40 Model: MacBook Pro 16" M1 Pro (A2485) · Board: 820-02100 Source: YouTube Fault class: Resistive semiconductor leakage ("soft short") on a secondary standby rail
Summary
A static 5 V / 180 mA draw with no boot. Diode mode on PP3V3_S2 read 0.082 V
(healthy reference > 0.400 V); resistance ~120 Ω. Because a 50–200 Ω leak trips no
short-killer and gets barely warm, location was done by controlled injection:
1.2 V at 1.5 A onto the rail with a thermal imager, which showed a ~3.5 °C rise on
a peripheral IC. Removing that IC restored the rail to 0.435 V and the board
negotiated 20 V.
Timeline
| Time | Evidence | Observation |
|---|---|---|
| 03:15 | [measured] |
USB-C meter: 5.15 V, continuous static 0.18 A (180 mA). |
| 09:40 | [measured] |
Diode mode PP3V3_S2 = 0.082 V to ground (ref > 0.400 V); resistance ~120 Ω. |
| 16:20 | [stated] |
Paul: a "soft short" (50–200 Ω) will not trip short-killers and does not get scorching hot, making it far harder to locate than a dead short. |
| 22:30 | [measured] |
Inject 1.2 V (1.5 A limit) onto PP3V3_S2; thermal imager shows a subtle ~3.5 °C rise on a peripheral logic IC. |
| 27:10 | [measured] |
Leaking IC desoldered; diode mode returns to 0.435 V; board negotiates 20 V. |
Measurements
| Time | Measurement | Value | Context |
|---|---|---|---|
| 03:15 | Voltage / current | 5.15 V / 0.18 A | Static draw |
| 09:40 | Diode mode | 0.082 V | PP3V3_S2 to ground |
| 09:42 | Resistance | 121.4 Ω | PP3V3_S2 to ground |
| 27:10 | Diode mode | 0.435 V | After repair |
Diagnostic reasoning
- Observation — static 180 mA at 5 V;
PP3V3_S2shows ~120 Ω instead of high impedance. - Stated mechanism — the fault is internal semiconductor junction degradation, not a cracked ceramic capacitor.
- Inference — a rail loaded to 120 Ω cannot hold 3.3 V, so the PMIC power-good flag stays low and blocks 20 V negotiation.
- Resolution — thermal imaging under controlled 1.2 V injection located the leaking IC; removing it restored normal rail impedance.
Repair procedure
- Run a diode-mode audit to isolate the leaking rail.
- Connect a bench supply at 1.2 V (not full rail voltage) to avoid damaging silicon.
- Watch the thermal signature under high-gain thermal imaging.
- Desolder the leaking IC with hot air.
- Re-verify the rail diode value and boot the board.
Claims audit
| ID | Claim | Evidence | Note |
|---|---|---|---|
| C1 | Soft shorts pull down PMIC power-good signals, locking the machine at 5 V without tripping overcurrent shutdown. | [inferred] |
The behavioural claim is well demonstrated; the internal power-good mechanism is inferred. |
| C2 | Low-voltage (1.2 V) injection is the safe way to find such leaks. | [stated] |
Sound practice; keep the current limit low and the voltage below the rail's nominal. |
Related cases
- M3 Pro Liquid Spill — 5V Stall, Missing SPMU Power-Good — a 5 V / 50 mA stall from an entirely different cause.
- Apple Silicon DFU Revive Loop — Inductor Solder Fatigue — rail integrity issues that only appear under dynamic load.
Provenance: condensed from the video's audio transcript (Google AI Studio); timestamps, refdes and values are as stated in the video and are not independently verified.