M1 Pro No Charge — Open SMBus SCL Trace
M1 Pro No Charge — Open SMBus SCL Trace
Status: repaired successfully · Channel: Paul Daniels · Published: 2024-11-01 · Runtime: 24:18 Model: MacBook Pro 16" M1 Pro (A2485) · Board: 820-02100 Source: YouTube Fault class: Open-circuit battery I2C clock line
Summary
After a customer's own battery replacement the machine would not charge. On the
charger it drew only 5 V / 0.02 A. Diode mode on SMBUS_BATT_SCL read OL at the
connector. Under the microscope, the trace from series resistor R5151 to J5150
was severed by a screwdriver slip. A 0.05 mm enamel jumper bridged the gap,
restoring clock continuity and the charging state machine.
Timeline
| Time | Evidence | Observation |
|---|---|---|
| 03:40 | [measured] |
New battery fitted by customer; runs on charger but draws 5 V / 0.02 A with the battery alone, and will not charge. |
| 08:15 | [measured] |
Diode mode on SMBUS_BATT_SCL = OL at the battery connector pins. |
| 14:20 | [measured] |
Microscope: trace from R5151 to J5150 severed by a tool slip. |
| 18:30 | [measured] |
Trace scraped, bridged with 0.05 mm jumper wire, sealed with UV solder mask. |
| 22:15 | [measured] |
Diode mode on SCL restored to 0.540 V; board negotiates 20 V / 3.4 A and charges. |
Measurements
| Time | Measurement | Value | Context |
|---|---|---|---|
| 08:15 | Diode mode | OL | SMBUS_BATT_SCL at connector pin |
| 14:20 | Resistance | OL | Across the severed trace gap |
| 22:15 | Diode mode | 0.540 V | SCL after jumper |
| 22:40 | Voltage / current | 20.0 V / 3.42 A | Charging |
Diagnostic reasoning
- Observation — a customer battery swap left a No Charge condition;
SCLis completely open. - Stated mechanism — tool slips during battery removal frequently sever
micro-traces running parallel to the board edge near
J5150. - Resolution — bridging the severed trace with an enamel jumper restores clock continuity, letting the BMS and charger re-establish communication.
Repair procedure
- Trace battery-connector pins in diode mode to find broken signal lines.
- Identify the severed copper trace under a stereomicroscope.
- Scrape enamel mask from both sides of the fracture.
- Solder a 0.05 mm jumper wire across the gap.
- Insulate with UV-curable green solder mask.
- Verify charging and power operation.
Claims audit
| ID | Claim | Evidence | Note |
|---|---|---|---|
| C1 | An open SCL halts the charger state machine, preventing any charging-current negotiation. |
[measured] |
Directly demonstrated. Note this is the opposite electrical fault (open) to the clamped-SDA case, with the same symptom. |
Related cases
[[m1max-smbus-tvs]]M1 Max No Charge — Shorted SMBus TVS Diode — the shorted-data-line counterpart.[[m2air-pullup]]M2 Air Battery Not Detected — Sheared SMBus Pull-Up — mechanical damage to the same bus during service.
Provenance: condensed from the video's audio transcript (Google AI Studio); timestamps, refdes and values are as stated in the video and are not independently verified.